How to calculate the air-to-cloth ratio of a baghouse
Formula, actual gas volume, cloth area and the one-compartment-offline check, with a worked example.
What it is
The air-to-cloth ratio (A/C), also called gas-to-cloth ratio or filtration velocity, is the actual gas flow passing through each square metre of filter cloth. It is the first number to check on any baghouse: too high and pressure drop, bag wear and emissions rise.
A/C = QA / Acloth [m³/min per m² = m/min]
Step 1: use actual, not normal, gas volume
The flow must be at baghouse inlet temperature and pressure. From normal conditions (0 °C, 101.325 kPa):
QA = QN × (273.15 + T) / 273.15 × 101.325 / pabs
Step 2: cloth area
For cylindrical bags, area per bag = π × D × L (side wall only). Total cloth = area per bag × bags per compartment × compartments.
Step 3: check with one compartment offline (N−1)
Pulse-jet or reverse-air baghouses that clean or are maintained compartment by compartment must still work with one compartment off line. Repeat the calculation with N−1 compartments; that is the governing value.
Worked example (invented numbers)
| Input | Value |
|---|---|
| Flow at normal conditions QN | 600,000 Nm³/h |
| Baghouse inlet temperature T | 120 °C |
| Absolute pressure at inlet | 98.3 kPa |
| Bags | Ø 160 mm × 8 m, 384 per compartment, 10 compartments |
| Step | Calculation | Result |
|---|---|---|
| Actual flow | 600,000 × 393.15/273.15 × 101.325/98.3 | 890,167 m³/h = 14,836 m³/min |
| Area per bag | π × 0.16 × 8 | 4.02 m² |
| Total cloth (10 compartments) | 4.02 × 384 × 10 | 15,442 m² |
| A/C, all online | 14,836 / 15,442 | 0.96 m/min |
| A/C, one offline (9 compartments) | 14,836 / 13,898 | 1.07 m/min |
What value is acceptable?
The design limit depends on the dust, the filter media and the cleaning method, and comes from the media maker or the baghouse supplier. As a published reference point, the US EPA cost manual lists iron oxide at 2.5 ft/min (0.76 m/min) for woven bags with shaker or reverse-air cleaning and 7 ft/min (2.13 m/min) for felt bags with pulse-jet cleaning. Treat those as screening values, not a design basis.
Do it in Fumora
Fumora’s calculator works through capture, gas conditioning and the baghouse in one chain, with the N−1 check built in. Its Plant Assessment mode checks an existing baghouse from measured flow.
Fumora overview · ISO 11057 filter media test in MechAtlas ↗
Sources: US EPA Air Pollution Control Cost Manual, Section 6 Chapter 1 (Baghouses and Filters). Worked examples use invented numbers. Results are engineering aids; check them against the maker's data and the governing standard.
Check your baghouse in Fumora
Enter your flow, temperature and bag layout; Fumora shows the all-online and offline-compartment filtration velocity.