FUMORA / BAGHOUSE CALCULATIONS

How to calculate the air-to-cloth ratio of a baghouse

Formula, actual gas volume, cloth area and the one-compartment-offline check, with a worked example.

What it is

The air-to-cloth ratio (A/C), also called gas-to-cloth ratio or filtration velocity, is the actual gas flow passing through each square metre of filter cloth. It is the first number to check on any baghouse: too high and pressure drop, bag wear and emissions rise.

A/C = QA / Acloth   [m³/min per m² = m/min]

Step 1: use actual, not normal, gas volume

The flow must be at baghouse inlet temperature and pressure. From normal conditions (0 °C, 101.325 kPa):

QA = QN × (273.15 + T) / 273.15 × 101.325 / pabs

Step 2: cloth area

For cylindrical bags, area per bag = π × D × L (side wall only). Total cloth = area per bag × bags per compartment × compartments.

Step 3: check with one compartment offline (N−1)

Pulse-jet or reverse-air baghouses that clean or are maintained compartment by compartment must still work with one compartment off line. Repeat the calculation with N−1 compartments; that is the governing value.

Worked example (invented numbers)

InputValue
Flow at normal conditions QN600,000 Nm³/h
Baghouse inlet temperature T120 °C
Absolute pressure at inlet98.3 kPa
BagsØ 160 mm × 8 m, 384 per compartment, 10 compartments
StepCalculationResult
Actual flow600,000 × 393.15/273.15 × 101.325/98.3890,167 m³/h = 14,836 m³/min
Area per bagπ × 0.16 × 84.02 m²
Total cloth (10 compartments)4.02 × 384 × 1015,442 m²
A/C, all online14,836 / 15,4420.96 m/min
A/C, one offline (9 compartments)14,836 / 13,8981.07 m/min

What value is acceptable?

The design limit depends on the dust, the filter media and the cleaning method, and comes from the media maker or the baghouse supplier. As a published reference point, the US EPA cost manual lists iron oxide at 2.5 ft/min (0.76 m/min) for woven bags with shaker or reverse-air cleaning and 7 ft/min (2.13 m/min) for felt bags with pulse-jet cleaning. Treat those as screening values, not a design basis.

Do it in Fumora

Fumora’s calculator works through capture, gas conditioning and the baghouse in one chain, with the N−1 check built in. Its Plant Assessment mode checks an existing baghouse from measured flow.

Fumora overview · ISO 11057 filter media test in MechAtlas ↗

Sources: US EPA Air Pollution Control Cost Manual, Section 6 Chapter 1 (Baghouses and Filters). Worked examples use invented numbers. Results are engineering aids; check them against the maker's data and the governing standard.

Check your baghouse in Fumora

Enter your flow, temperature and bag layout; Fumora shows the all-online and offline-compartment filtration velocity.